Holter Monitor TLC 5000
Key features Of Contec Holter Monitor TLC 5000 24hr :-
These are the Key Feature of Holter Monitor TLC 5000
1. The recorder can work stably, dependable and durable.
2. Be provided with the capability of anti-jamming and shock-pro.
3. Small volume with OLED screen. The resolution is 160*128.
4.Be provided with functions of waveform preview, record review and event marking.
5. Accurate record of the start time of the data sampled owing to the real-time clock of itself.
6.Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
7.The maximum capability can be 2 GB.
8.The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
9. Record waveform details in extension by the design of high precision and sampling frequency.
10.Record the state of pacemaker exactly by higher sampling frequency.
11. Record 24-hour DECG with the same standard of the ECG. The features of software
1.Quick and accurate analysis system.
2.With 12 leads synchro analysis , QRS search can be more exactly.
3.There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicative User-defined templates could almost identify every kind of pathologic waveforms.
4.Optional main channel.
5.Agile and exact “Atrial Fibrillation” analysis.
6.The function of pacing analysis could analyse all pacemakers.
7.Many pacine modules have been added.
8.Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
9.The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
10.Print report expediently.11.Perfect function of case management.
12.With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
13.”Sleep breath pause syndrome analysis”, the physician could print sleep asphyxia analysis report and diagnose.
14.”HRT” analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
15.”T Wave alternation” analysis is a important index on judging and preventing Arrhythmia .
16.The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.
Number of channels12 channelsSampling rate10000HzSampling accuracy12bitRecording time24 hPower2 batteries in size 5InterfaceUSB2.0Scale voltage1mV±5%Standard Sensitivity10 mm/mV±5%Noise level≤30μVCMRR≥60dBFeathers of low frequencyTime constant>3.2sScan speed25 mm/s±5%Enduring polarization voltage±300mVLeast measure signal50 µV p-pProduct safety typeType B (Internally powered)Size111 mm(L)*60 mm(W)*25 mm(H)Net Weight102g (Without battery)